Conductor Damage Checker

Conductor  Damage Checker - Alat Uji SNI
Aplikasi: - memeriksa tingkat kerusakan kawat konduktor kabel  - menilai apakah desain dan struktur dari terminal klem sekrup dapat merusak kawat konduktor kabel  - memeriksa apakah terminal klem sekrup tahan stres/tarikan selama Model: CPL-A11
Sumber daya: AC 220V, 50Hz
Dimensi: 600 x 600 x 750  Sampel uji: Plug, steker, kabel, kabel fleksibel, kabel konduktor
proses penggunaan normal. Sesuai standar: SNI IEC 60884-1 Gambar 11

Conductor Damage Checker


Terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s). Compliance is apparatus of checking damage . The terminal is placed in the test apparatus according to tester and fitted with rigid, solid, stranded and/or flexible conductor(s), according to standard first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to standard. The length of the test conductor shall be 75 mm longer than the height (H) specified in standard. The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in standard. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min. The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in standard. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor. A mass as specified in standard is suspended from the end of the conductor. The duration of the test is approximately 15 min. During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use.

Platen Diameter
Circular Radial/Diameter (mm)
Radial Rate of Testing
Test long Period
Platen gap with terminal(H)(mm)
Mass for Conductor(Kg)
Conductor Sample Test
: 75mm
: 37.5/75
: (10 ± 2) rpm
: Approximately 15 minute
: 260 & 280 (± 15)
: 0.3, 0.4, 0.7, 0.9, 1.4, 2.0
: 75mm longer than H